The Bitmain Antminer S21+ uses SHA-256 for Bitcoin and compatible networks. The 216 TH/s reference version consumes 3564 W with typical efficiency of 16.5 J/TH. Air cooling requires suitable ventilation, Ethernet and single-phase 220-277 V AC power.
Version selection: 216 TH/s / 3564 W; 225 TH/s / approximately 3713 W; 235 TH/s / approximately 3878 W. The latter two power estimates are calculated at 16.5 J/TH; confirm the supplied batch label.
Bitmain Antminer S21+ manufacturer specifications. Compare Bitcoin miners and review mining income estimates. At 3564 W for 24 hours, miner energy use is 85.54 kWh before external cooling. Actual revenue and payback depend on network conditions and total costs.
Technical Specifications
| Product Glance | Value |
|---|---|
| Model | Bitmain Antminer S21+ |
| Crypto algorithm/coins | SHA-256 / Bitcoin; other SHA-256 networks require matching pool support |
| Typical hashrate | 216 TH/s reference; confirm selected batch and mode |
| Power on wall @35℃, Watt | 3564 W reference; manufacturer reference configuration; supplied versions may differ; reference condition: 25 C inlet air |
| Power efficiency on wall@35℃ | 16.50 J/TH calculated from 3564 W / 216 TH/s; same reference configuration; reference condition: 25 C inlet air |
| Detailed Characteristics | Value |
|---|---|
| Power Supply | |
| Phase | 1 (single-phase AC) |
| Input voltage, Volt | Single-phase 220-277 V AC |
| Input frequency range, Hz | 50-60 Hz |
| Input max current, Amp | 20 A maximum input rating |
| Hardware Configuration | |
| Networking connection mode | RJ45 Ethernet 10/100 Mbps |
| Server size(length*width*height, w/o package), mm | 450 x 219 x 293 mm (L x W x H) |
| Server size(length*width*height, with package), mm | 630 x 350 x 430 mm (L x W x H; confirm shipment packaging) |
| Net weight, kg | 21.5 kg |
| Gross weight, kg | 24.5 kg (with package) |
| Noise@30℃, dBA | 76 dBA (manufacturer reference; maximum fan speed) |
| Environment Requirements | Value |
|---|---|
| Storage temperature, °C | -20 to 70 °C |
| Operation humidity(non-condensing), RH | 10-90% RH, non-condensing |
| Operation temperature,°C | -20 to 45 °C ambient; altitude derating applies |
| Operation altitude, m | ≤2000 m; above 900 m reduce maximum ambient temperature by 1 °C per additional 300 m |
| What's in the Box | Value |
|---|---|
| Original factory mining machinery | ✓ |
| Power supply | ✓ |
| Shockproof packaging | ✓ |
(1) The hashrate value, power on wall, and power efficiency on wall are all typical values. The actual hashrate value fluctuates by ±3%, and the actual power on wall and power efficiency on wall fluctuate by ±5%.
(2) Caution: Wrong input voltage may cause server damaged.
(3) The noise is loudest when the fan is under maximum RPM(rotation per minute).
(4) When the server is used at an altitude from 900m to 2000m, the highest operating temperature decreases by 1℃ for every increase of 300m.